LUGB series Vortex flow meters are designed for measuring the volume/mass flow of liquids, gases and steam based on Karman vortex principle.
Adopting advanced differential algorithm along with measurement of isolation, shielding and wave filtering, LUGB series vortex flow meters have the advantages of immunity on vibration and noise. Meanwhile, the liabilities of LUGB series vortex flow meters are well guaranteed by unique sensor packaging technology.
Application: Gas / Liquid / Steam
Size: 15 – 300mm
Supply: 24 V DC / Battery
Output: Pulse /mA/MODBUS RS485
Display: LCD Type
Housing /Shedder Bar: SS316
Temp & Pressure Compensation: Available
Flow rate: 1.2 – 2000m3/h (Liquid), 5 – 11000m3/h (Gas)
Temperature: -20 to +350ºC
Connection: Threaded / Flanged
Accuracy: 1% of rate
Ex Version: Available
Chemical, Petrochemical and
Process Industries
Fertilizer Industries
Pharmaceutical Industry
Food Industry
Drug Industries
Sugar Industries
Beverage Industries
Paper and Pulp Industries
Aluminum Industries
Steel Industries
Mining Industries
Dredging Industries
Water and Waste - Water
Management
And many
Line size: 10 to 2000mm
Process connection: Flange
Power supply: 24VDc/80 to 300VAC/Battery operated
Display: Integral/Remote
Temp: upto45/ 90 Deg C
Pressure: 5 to 40Kg/Cm2
Output: 4-20mA/Pulse/0-20VDc/Relay
Communication Interface : RS232/RS485/HARt/GSm/GPRS
Sensor Lining : Hard rubber/PTFE/Neoprine
Electrode : SS316/HastelloyC/Titaneum
Protection : IP65/67/68
Beer & Beverages
Hot Water Appliances
Distribution Measurement
Chemical Dosing Equipment
Medical Equipment
Hydraulic Systems
Automotive
Flow range: 0,5..20 l/min*
Accuracy: ±1,0 % of reading
Reproducibility: ±0,3 % of reading
Liquids: translucent liquids / water, chemicals, oils
Operating Pressure: max. 16/250 bar
Temperature: -20..90°C
Viscosity range: up to 1000 Cst
Output: 100..2000 Hz
Output: 100..2000 Hz
Sensitivity : ±6000 pulses / liter
Signal form : Square wave
Amplitude : see power supply
Power Supply: 5..24 Vdc, 12..36 mA
Electrical connection: 15 cm,3 wire flat cable / connector
Process connections: 3/8" BSP male/female
Removable element structure
Easy installation and maintenance
Long term clear reading
Inter-exchangeable spare parts
Magnetic drive
Sensitive action
Small pressure loss
Long working life,etc.
Size: 1/2 – 1”
Display: Mechanical counter
Wetted Material: Brass / CI
Pressure: 1Mpa
Flow rate: 1.5 – 15m3/h
Temperature: 0 to +45ºC
Connection: Threaded / Flanged
Accuracy: 2% FS
WORKING CONDITION
Water temperature:=40°C
Water pressure:=1MPa
MAXIMUM PERMISSIBLE ERROR
1.In the lower zone from Qmin inclusive up to but excluding Qt is ±5%
2.In the upper zone from Qt inclusive up to and including Qs is ±2%
Note:Technical data conform to international standard ISO4064.
Size: 50 – 500mm
Display: Mechanical counter
Wetted Material: CI
Pressure: 1.6Mpa
Flow rate: 15 – 1500m3/h
Temperature: 0 to +45ºC Cold water / 90ºC Hot water
Connection: Flanged
Accuracy: 2% FS
Class: ISO 4064 Class B
Name: LXSZ Series Wireless Remote valve-control dry water meter
Model: LXSZ
Output Power: 50mW
Receiver: -108dB
Sensitivity: -108dB
Transmission: 165*85*111mm
Distance Dimension Clicks : 807
LXSZ series wireless remote valve-control dry water meter is high-tech integrative product. This series meter uses advanced wireless transmission technology. Through microelectronic control circuits, it converts the pulse signals of traditional mechanical meter into electrical signals. Then the metering data is transmitted to background platform through GPRS network automatically, or it can be collected by a hand-held wireless unit from outside of the houses and after that downloaded to a computer through USB port
Line size: 15 to 500mm
Process connection: Thread/Flange
Temperature: upto45/ 90 Deg C
Pressure: Max 1.6MPa
Output : Mechanical/Pulse
Fluid entering the meter first passes through an inlet flow straightener that reduces its turbulent flow pattern. Fluid then passes through the turbine, causing the turbine to rotate at a speed proportional to fluid velocity. As each turbine blade passes through the magnetic field generated by the meter's magnetic pickup, an AC voltage pulse are generated. These pulses provide an output frequency that is proportional to volumetric flow.
Size: 4 – 200mm
Supply: 24 V DC / Battery
Output: Pulse /mA/MODBUS RS485
Display: LCD Type
Housing Material: SS304/SS316
Rotor Material: 2Cr13/CD4MCu
Bearing Material: Tungsten Carbide
Flow rate: 0.04 – 800m3/h
Temperature: -20 to +150ºC
Connection: Threaded / Flanged
Accuracy: +/-0.5% or 1% of rate
Ex Version: Available
The operation of the Gas Turbine Meter is based on the measurement of the velocity of gas. The flowing gas is accelerated and conditioned by the meters straightening section. The straightening vanes prepare the gas flow profile by removing. undesired swirl, turbulence and asymmetry before the gas flows to the turbine wheel. The dynamic forces of the flowing fluid cause the rotor to rotate.
The turbine wheel is mounted on the main shaft, with special high precision, low friction ball bearings. The turbine wheel has helical blades that have a known angle relative to the gas flow. The conditioned and accelerated gas drives the turbine wheel with an angular velocity that is proportional with the gas velocity.
Size: DN25 – 400mm
Supply: 24 V DC / Battery
Output: Pulse /mA/MODBUS RS485
Display: LCD Type
Body Material: SS304/SS316/CA/CS
Rotor Material: Aluminium / ABS Plastic
Bearing Material: SS304
Flow rate: 2.5 – 8000m3/h
Temperature: -20 to +80ºC
Connection: Threaded / Flanged
Accuracy: +/-1% or 1.5% of rate
Ex Version: Available
Paddle wheel flow meters belong to the category of insertion type flow meters. The rotating paddle wheel generates a signal in proportion to the velocity of the moving fluid which is read in terms of the flaw rate. Because the pipe's cross-sectional area is known and remains fixed the average velocity is an indication of the flow rate.
Line Size : 15 to 300mm
Input Voltage: 12 to 24 VDC
Connection: Thread/Flange
Output Type: Pulse /4-20mA
Temp: 0-50/70 deg C,
Pressure : 5/20bar Max
Body : P. P/SS
Paddle : Delryn/SS
Protection : IP65
MX-SERIES meters offer flexibility and robust design
Superior performance and reliability.
Made from billet Stainless Steel (316L) or Aluminium (6061-T6)
MX-SERIES offers enhanced flexibility of interchangeable pulse / Digital displays.
The robust construction also offers increased pressure rating (up to 2000psi).
Billet construction contributes to increased accuracy and even better repeatability.
Hazardous Area approvals are also available.
MX Series meter is checked for accuracy with specific “K Factor”
Size: ¼ ---- 4” (MX006 --- MX100)
Output : Reed / Hall Pulse /mA(with display only)
Construction: PP/Aluminium/SS316
Flow rate: 0.5 LPH – 1200LPM
Rotor Options: Standard (for fluid below 1000cps) High Viscosity (for fluid above 1000cps)
Temperature: -40 to +150ºC
Connection: Threaded / Flanged
Pressure: Up to 550bar
Accuracy: +/-0.5% (0.25% with reduced range)
Approval: Pulse O/p Module Switching Option
NPN Open Collector
Intrinsically safe
II I G Ex ia IIC T6 (ATEX, CSA, FM)
NAMUR
Intrinsically safe,
Ex II 1 G Ex ia IIC T6/II 1 D Ex ia D 20 T115 °C
Approved ATEX, IECEx
Simple to install & low in cost
No moving parts-maintenance free reliability
Optimal temperature compensation
Can operate in temperatures up to 248ºF (120ºC)
Have a maximum working pressure of 4350 PSI (300 bar)
Choice of output signal
Chain of 8 LED´s-Integrated flow rate/set point indication
Fast response time for flow
Excellent low flow sensitivity
Insensitive to dirt and on most particles
Available in threaded, flange, sanitary and adjustable insertion length connections
Supply : 24 V DC
Set Point Range: Liquid – 0.04 – 2m/s / Oil – 0.1 – 4m/s
O/p: 4 – 20mA & PNP / Relay
Protection: IP65
Accuracy: +/-10%
Process connection : Threaded / Flanged / Sanitary
Temperature : -10 to +120ºC
Wetted Material : 316 Stainless Steel
Enclosure Material : Glass filled nylon / Aluminium
Max Pressure : 4350 PSI (300 Bar)
Thermal Mass flow meter provides high performance. Thermal technology offers advantages in accuracy, sensitivity & turn quality components & the latest technology are combined to provide reliable, compact meter & controller. Mass controller series combines flow transducer with an electromagnetic proportional valve. Controller uses a 0 -5 VDC linear set-point signal supplied from the local set-point pot or from remote source.
Application: Gas
Size: 1/4 – 1”
Supply: 24 / 15 V DC or 115 / 220 V AC
Output: 4 – 20mA / 0 – 5V Dc
Display: LCD Type
Wetted Material: SS316 / Tapcon-plastic
Pressure: 500psig Max
Flow rate: 0 – 1500SLM
Temperature: 0 to +50ºC
Connection : NPT F
Accuracy: 1% FS
Turn down Ratio : 100 : 1
Control Valve: Electromagnetic (NC)
Control signal: 0 – 5 V DC (Integral or Remote)
For dirty liquids, a certain amount of air bubbles or suspended solids contain
Excellent low flow measurement ability, low to 0.05 m/s.
A wide range of flow measurement, high flow rate can reach 12m/s.
Automatically signal gain adjustment.
User-friendly configurations.
4-20mA and dual relay output
Accuracy: 2.0% Calibrated span
Line Size: DN15 – DN4000
Output: 4-20mA/Pulse/Relay
Supply: 115 – 250 V AC / 24 V DC
Flow range : -0.05 to 12m/s
Display Type: Wall Mounting / Hand Held
Temperature: -40 to +250ºC
Mounting Type: Clamp on / Insertion
Cable : 6 – 300m
Accuracy: +/-0.5 - 2%
World advanced technologies are applied.
Various installation methods: Clamp-on transducers and Insertion transducers can be hot-tapped.
Operation is user-friendly, simple and easy.
The design makes the mounting process very simple, and no special skills or tools are required.
High precision and reliability, independent of fluid conductivity, wider applications than magnetic flow meters.
Wide measuring range, can measure low flow rate up to 0.003m/s.
Bi-directional flow measurement.
Spool-piece transducer for best accuracy and best stability in the long run.
No moving parts, no pressure drop, no need of maintenance.
Display for total flow, flow rate, velocity and meter running status.
Accuracy up to 0.5% ~ 1.0% reading accuracy before out of factory.
The high-temperature transducer is suitable to liquid of -40℃ ~ 250℃.
Explosion-proof products, ATEX certified.
Wireless real-time GPRS module available.
Line Size: DN15 – DN4000
Output: 4-20mA/Pulse/RS485/RS232/Relay
Supply: 115 – 250 V AC / 24 V DC
Flow range : -12 to 12m/s Bidirectional
Display Type: Wall Mounting / Hand Held
Temperature: -40 to +2500C
Mounting Type: Clamp on / Insertion
Cable : 6 – 300m
Accuracy: +/-1 - 2%
Approval: ATEX
Pumps diesel, petrol, av gas, kerosene and lubricating oils up to SAE 30
Ideal for high volume aviation fuel transfer
Supplied with a 2.4 m (8 ft) anti-static rubber delivery hose and nozzle, and 1.06 m (3.5ft) two piece threaded suction tube Pumps easily in both directions
Lockable handle and built-in nozzle holder
In-built strainer
50 mm (2”) bung adaptor
Optional HNU nozzle for unleaded fuel
10 year warranty
10 year parts
Supply 12 / 24 V DC / 250 V AC
Discharge 40 / 70 LPM
Protection IP55
On / Off switch Included
Cable 2m with Alligator connector
Media Diesel Only
Fuse Yes
Duty Cycle 30min
Section / Delivery House 1” X 2m / 1” X 4m
Oval gear design
Low pressure drop allows for gravity and pump (in-line) applications
Register cap can be easily removed and rotated to every 90° orientation for display reading
Supplied with integrated mesh strainer
10 year warranty
10 year parts availability
Wetted Components: Aluminum, Zinc plated Carbon Steel, PEI Resin, Viton
Accuracy: ± 1% of reading
Accuracy: 3 - 80 L/min (0.8 - 21 US gal/min)
Max. Pressure: 1000 kpa (145 psi, 10 bar)
Register – Totaliser: 0 – 999,999 L (gal)
Register – Reset: 0 – 999.9 L (gal)
Max. Temp: 80° C (176° F)
Inlet Thread: 1” BSPT, 1” BSPPL(G) or 1” NPT female
Outlet Thread: 1” BSPT, 1” BSPPL(G) or 1” NPT female
Weight: 1.2 kg (2.6 lbs)